- Производитель:
- Sigma-Aldrich
eCl@ss: | 32161000 |
Cell Structure
The MillicoatTM screening kit contains individual 96-well plates for fibronectin, vitronectin, laminin, collagen I & collagen IV.
PROCEDURE:
NOTE: Optimal assay performance is obtained using subconfluent cell cultures. This can be achieved by splitting the cells 1 to 2 days prior to performing the assay.
1. Rehydrate the strips with 200 mL of PBS per well for at least 15 minutes at room temperature. Remove the PBS from the rehydated strips.
2. Prepare a single cell suspension, preferably using a non-enzymatic dissociation buffer. Optimum cell density may be determined by titration of the cells. A common starting range is between 1x10E05 to 1x10E07 cells/mL.
3. Add 100 mL of the diluted cell suspension to each well. Incubate the plate at 37°C for 1 hour in a CO2 incubator. Gently wash the plate 3 times with PBS containing Ca2+/Mg2+ (200 mL/well).
4. Add 100 mL/well of 0.2% crystal violet in 10% ethanol to each well. Incubate for 5 minutes at room temperature. Remove the stain from the wells. Gently wash the plate 3 times with PBS (300 mL/well).
5. Add 100 mL of Solubilization Buffer (A 50/50 mixture of 0.1M NaH2PO, pH 4.5 and 50% ethanol) to each well. Allow strips to incubate and gently shake at room temperature until the cell-bound stain is completely solubilized; approximately 5 minutes.
6. Determine the absorbances at 540 - 570 nm on a microplate reader.
MILLICOAT is a registered trademark of Merck KGaA, Darmstadt, Germany
Quality Level | 100, |
species reactivity | human |
Торговая марка | Chemicon®, Millicoat® |
application(s) | activity assay: suitable, cell analysis: suitable (cell based assay) |
input | sample type: human embryonic stem cell(s) sample type pancreatic stem cell(s) sample type hematopoietic stem cell(s) sample type induced pluripotent stem cell(s) sample type mesenchymal stem cell(s) sample type neural stem cell(s) sample type: mouse embryonic stem cell(s) sample type epithelial cells |
detection method | colorimetric |
shipped in | wet ice |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.