- Производитель:
- Sigma-Aldrich
Кат. номер |
ZRB1293-4X25UL |
ZRB1293-25UL |
Each ZooMAb® antibody is manufactured using our proprietary recombinant expression system, purified to homogeneity, and precisely dispensed to produce robust and highly reproducible lot-to-lot consistency. Only top-performing clones are released for use by researchers. Each antibody is validated for high specificity and affinity across multiple applications, including its most commonly used application. ZooMAb® antibodies are reliably available and ready to ship when you need them.
Quality Control Testing
Evaluated by Western Blotting in Human Heart tissue lysate.
Western Blotting Analysis: A 1:1,000 dilution of this antibody detected CACNA1C in Human Heart tissue lysate.
Tested applications
Immunocytochemistry Analysis: A 1:100 dilution from a representative lot detected CACNA1C in L6 cells.
Immunohistochemistry (Paraffin) Analysis: A 1:100 dilution from a representative lot detected CACNA1C in human heart and human kidney tissue sections.
Note: Actual optimal working dilutions must be determined by end user as specimens, and experimental conditions may vary with the end user
Target description
Voltage-dependent L-type calcium channel subunit alpha-1C (UniProt: Q13936; also known as Calcium channel, L type, alpha-1 polypeptide, isoform 1, cardiac muscle Voltage-gated calcium channel subunit alpha Cav1.2, CACNA1C) is encoded by the CACNA1C (also known as CACH2, CACN2, CACNl1A1, CCHL1A1) gene (Gene ID: 775) in human. CACNA1C is a multi-pass membrane protein that serves as a pore-forming alpha-1C subunit of the voltage-gated calcium channel that gives rise to L-type calcium currents. It colocalizes with ryanodine receptors in distinct clusters at the junctional membrane, where the sarcolemma and the sarcoplasmic reticulum are in close contact. It mediates the influx of calcium ions into the cytoplasm, and thereby triggers calcium release from the sarcoplasm. It is also reported to play a role in excitation-contraction coupling in the heart and is required for normal heart development and normal regulation of cardiac rhythm. Its phosphorylation by protein kinase A at seine 1981 is shown to activate the channel. CACNA1C is also shown to be essential for normal contraction of smooth muscle cells in blood vessels that is required for normal blood pressure regulation. Its activity can be inhibited by treatment with nifedipine and dihydropyrdines. Mutations in CACNa1C gene are known to cause long QT syndrome that is characterized by a prolonged QT interval on the ECG and polymorphic ventricular arrhythmias. This ZooMAb® recombinant monoclonal antibody, generated by our propriety technology, offers significantly enhanced specificity, affinity, reproducibility, and stability over conventional monoclonals.
Physical form
Purified recombinant rabbit monoclonal antibody IgG, lyophilized in PBS, 5% Trehalose, normal appearance a coarse or translucent resin. The PBS/trehalose components in the ZooMAb formulation can have the appearance of a semi-solid (bead like gel) after lyophilization. This is a normal phenomenon. Please follow the recommended reconstitution procedure in the data sheet to dissolve the semi-solid, bead-like, gel-appearing material. The resulting antibody solution is completely stable and functional as proven by full functional testing. Contains no biocide or preservatives, such as azide, or any animal by-products. Larger pack sizes provided as multiples of 25 μL.
Reconstitution
300 μg/mL after reconstitution at 25 μL per vial. Please refer to guidance on suggested starting dilutions and/or titers per application and sample type.
Storage and Stability
Recommend storage of lyophilized product at 2-8°C; Before reconstitution, micro-centrifuge vials briefly to spin down material to bottom of the vial; Reconstitute each vial by adding 25 μL of filtered lab grade water or PBS; Reconstituted antibodies can be stored at 2-8°C, or -20°C for long term storage. Avoid repeated freeze-thaws.
Disclaimer
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Quality Level | 200 |
biological source | rabbit |
recombinant | expressed in HEK 293 cells |
antibody form | purified antibody |
antibody product type | primary antibodies |
clone | 1F20, recombinant monoclonal |
description | recombinant, expressed in HEK 293 cells |
product line | ZooMAb® |
form | lyophilized |
mol wt | calculated mol wt 248.98 kDa","observed mol wt ~250 kDa |
species reactivity | human, rat |
species reactivity (predicted by homology) | monkey, mouse, bovine |
packaging | antibody small pack of 25 µL |
enhanced validation | recombinant expression |
application(s) | immunocytochemistry: suitable","immunohistochemistry (formalin-fixed, paraffin-embedded sections): suitable","western blot: suitable |
isotype | IgG |
epitope sequence | N-terminus |
conjugate | unconjugated |
Protein ID accession no. | NP_955630, |
UniProt accession no. | Q13936, |
shipped in | ambient |
storage temp. | 2-8°C |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.